PharmaPort™ -20C
Specifications*
                    PP-20 web.jpg
Dimensions
Exterior: 80"L × 52.5"W × 58.5"H
(203 × 133 × 149 cm, nominal)
Interior: 50.5"L × 44"W × 46"H
(128 × 111 × 116 cm, nominal)
Payload Dimensions: 48"L × 40"W × 44"H
(122 × 102 × 112 cm, nominal)
Payload Weight: 1102 lbs (500 kg)
Container Weight (Net): 1200 lbs (544 kg)
Electrical
Recharge Mode: 100-240V, AC (nominal) 50/60Hz, 20 amp circuit with international plug adapter. Universal power input for global compatibility, plug adapters included for all international outlets. System must be recharged between shipments. Full recharge from room temperature requires 18 hours.
Transport Mode: Self-powered, no external connection required. Refrigeration compressors is idle during transport, regenerative eutectic plate provides cooling on demand by computer controlled air flow system.
 
Temperature Performance
Setpoint: Fixed at -21°C; no user adjustment
Total Temperature Tolerance from Set Temperature: +/- 2.0°C
Ambient Temperature Tolerance: -40°C to +60°C
Hold Times, Transit Mode: 
@ 23°C ambient: 31 hours below -20°C, 38 hours below -15°C
@30°C ambient: 27 hours below -20°C, 32 hours below -15°C
Ambient Temperature Tolerance: -40°C to +60°C*
*if ambient temperature drops below -23°C set point for a long period, temperature of container will also drop. 
Shipping and Logistics
  • Accommodates standard 40" × 48" pallets(101 × 122 cm, nominal)
  • Four-sided forklift access
  • Flat bottom for roller conveyor transport
  • Secure, customs-tagable locking device
  • Rugged design withstands abuse of commercial transportation

 

*Specifications subject to change without notice.
Print Page Print Email us Email FaceBook  Linked In  Twitter Share